Emergency measures for the use of liquid sulfur trioxide

2020-03-22


Althoughliquid sulfur trioxidePressure vessels and equipment such as storage tanks are equipped with safety valves, pressure gauges, liquid level gauges and thermometers, and shall be equipped with safety devices with remote recording and alarm functions of pressure, liquid level and temperature. Contact with reducing agent, alkali and active metal powder will also be avoided during use, especially avoiding contact with water and keeping away from flammable and combustible materials, but danger is still everywhere. Once it happensliquid sulfur trioxideWhat emergency measures should we take in case of emergency such as leakage?

 

1. First-aid measures

Inhalation: quickly leave the scene to the fresh air, keep the respiratory tract unobstructed. If breathing is difficult, give oxygen. If breathing stops, immediately carry out artificial respiration and seek medical treatment in time;

Ingestion: Gargle with water, drink milk or egg white, seek medical attention as soon as possible;

Skin contact: Immediately remove contaminated clothing and rinse with plenty of running water for at least 15 minutes. If the condition is serious, seek medical attention immediately;

Eye contact: immediately lift the eyelid, rinse thoroughly with a large amount of flowing water or normal saline for at least 15 minutes, and seek medical advice promptly.

 

2. Fire extinguishing measures

 liquid sulfur trioxideAlthough it is not combustible, the leakage source should be cut off when there is a fire around, and then appropriate extinguishing agent should be selected to extinguish the fire according to the cause of the fire; the container should be moved from the fire site to the open area as much as possible until the fire is extinguished. Firefighters must wear filtering gas masks (full face masks) or isolation breathing apparatus, wearing full-body fire protection clothing, in the upper wind direction to put out the fire. Kan

 

3. Emergency treatment for leakage

The demarcation of the warning zone is based onliquid sulfur trioxideThe flow and vapor diffusion affect the area defined by the evacuation of unrelated personnel from the side wind and upwind to the safe area. It is recommended that emergency response personnel wear positive pressure self-contained air respirators and acid-base protective clothing. Do not touch broken containers and spills until you put on appropriate protective clothing.




REAL-TIME NEWS

Yangzhou Jiaming Environmental Protection Technology Co., Ltd.

Address: Fangxiang Industrial Park, Hanjiang District, Yangzhou City, Jiangsu Province

Contact: Tang Jiafu13951439212

Contact: Wu Weimin13952058396

Two-dimensional code

Scan QR Code


Copyright:Yangzhou Jiaming Environmental Protection Technology Co., Ltd.